Moving from gas to electric, my current gas oven is 13 amp which the new electric oven will also be so I'm confident that will work, but I'm worried about the hob. Hi all, Currently in the process of modernising our extremely old kitchen. Power level 3. 3/5. From £9. You could fit a plug to the hob with a 13A fuse in it. 1 x 59 x 52 cm (H x W x D) 4 zones. Hob. Warranty: 1 year labour/10 years parts. 49 Inc Vat. Available with or. Search Activating the button will move focus to the expanded search input fieldThere needs to be a gap of at least 65cm between your hob and the cooker hood or ceiling. 99 More info. 3A. Buy 13 A Electric Plugs at Screwfix. (100) £. (65) £. com. Child Safety Lock Mechanism. Type. Odourless. 60 days free credit available. 4 x Plates. Dimensions (cm) - H5. Front-mounted touch controls. I'd be grateful for any help with the following. Screwfix - SCHNEIDER ELECTRIC LISSE SOCKETS. Suitable for use on domestic stoves, furnace chimneys, industrial ovens and exhausts. 97 » View product. Hi, I've managed to smash my ceramic hob with a bottle of olive oil of all things. Blomberg MIN54308N 58cm Electric Induction Technology Hob - Black. Perhaps I should persuade the my mother-in-law to get a decent electric hob ! Sam, Jun 16, 2006 #5. 5m The oven has a cable with a 13amp fuseNomad24 New Member. 7kW hob. The old hob was fed from a 4mm cable. I have recently been told that I can't fit a gas hob in my kitchen as it's to close to the window. All on a 40amp breaker or would it be best to de-rate down to 32amp due to diversity. Pay no interest when you pay your full balance within 9 months 29. #2. Screwed Faceplate. 6 So my cooker circuit is not adequate enough. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. 96 Inc Vat. The control switch has to be within 2 meters of the oven/hob, if they are seperated the control switch should be within 2 meters of either appliance. Total Product Weight. 79 Inc Vat. 00 Save £10. Buy a bundle. £289. Job I was called to today. 9% APR representative (variable)* +2 more offers. Circuit 6 is currently used for our electric double oven. Three phase is not common for domestic, however split phase is very common, you need to find out if really 3 phase or split phase, and careful on voltage, across 3 phase supply phase to phase UK 400 volt, across split phase supply phase to phase is 460 volt. He told her that she will need to get an electrician to carry out the electrics. Write a review. Under worktop oven. 45. Buy a bundle. Hobs are at the heart of any kitchen, and are great for creating quick, delicious meals for friends and family. Boost function. Repair Service Contact. 47 amps. I have bought an oven unit, it has 2 wooden struts which run along the top. This stainless steel hob is compact and lightweight, and has variable independent heat control and power on the two separate cooking plates: 1500W and 750W. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. One of the biggest advantages is the ease of cleaning as you just have a sheet of glass to wipe over, with no burnt on food. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. £950 (£40. about to purchase a separate electric oven and electric hob, at the moment I have a cooker point supplied with 10mm cable from consumer unit. sinewave Screwfix Select. There is an approx 8m run in plaster and across a ceiling (no insulation). Our Lowest Price Ever. #4. They know exactly what tradespeople need to master every challenge. 97 » View product. FREE next day delivery available, free collection in 1 minute. FREE next day delivery available, free collection in 1 minute. Free returns. 13 Inc Vat. com. Have asked the builder to lay in the 4mm cabling for the oven. Deals and Offers. 8kw. Electrolux KGS7536X 5 Burner Stainless. 3/5. 6. So I am wondering does diversity apply to the combined total wattage of both the appliances or just the oven. The landlord wasn’t able to confirm if there. Hobs are at the heart of any kitchen, and are great for creating quick, delicious meals for friends and family. If you had a gas hob, the minimum distance would be 150mm under the gas regs. com. £ 3. Pay no interest when you pay your full balance within 9 months 29. #8. 2KW which is 32 Amps, the oven is on top of that. sdfuk New Member Hi my Neff (T68TS61N0) hob no longer works - power button goes on them apparently. 5mm2 ring which is protected by a 32A MCB. The safety lock feature ensures touch controls are not operated by accident. ★★★★★ Read 67 reviews. 35kw. What is selected store? Use my current location. Gas. 5mm cable, but you need to change some jump connections on the unit itself depending on the power source; But it will not work at full capacity which defeats the. (At the moment we have a seperate gas hob) The old oven and gas hob will be replaced with: - Induction Hob - the rating is 6. 2 x Plate Sizes. Do they go any bigger and would it be feasible to fit. £240 for a complete new hob - £220 for just the replacement glass top - if you don't feel competent to replicate how it was connected it's an easy. Induction hob featuring Autoconnect technology LinkSense, allowing wireless RF connection to compatible hood. £72. Some have bigger terminals than others which makes the job easier, other wise change it to the one suggested above. To cook food with less energy you need to reduce the energy loss, so less heat into atmosphere more into food. The gas hob is to be removed and replaced with an electric induction hob, plus electric oven (oven rated at 16A). So in your case we would have 3. robertpstubbs Screwfix Select. The Russell Hobbs 15199 Electric Mini Hob is a convenient portable yet powerful electric hob. MGW Screwfix Select. terrymac Screwfix Select. Featuring four electric hobs, with power ranging from 1. The built-in Neff B57CR22N0B Slide & Hide Electric Oven is spacious and packed with plenty of different functions that allow you to cook the way you want. 5mm H05 flex for oven to outlet plate as specified in manufacture manual says the max wattage for this size cable is 3860w. 6 / 5 (60 Reviews) 4 induction zones, for safe responsive cooking. Screwfix Community Forum. When the electrician comes back will ask him to connect to consumer unit end and also for the oven. #14. Allow to dry between coats. Hi all, planning to replace my electric ceramic hob for an induction one. Skip to content. The installation instructions for the induction hob state that it requires direct connection to the mains and requires a 32A. 0800 324 7818. The old chap over the road has asked asked for help replacing an electric hob. The switch will act as an isolation switch for both. Each of the ovens is 5. 25. 99Inc Vat. Have a good ‘un Bazza, Oct 2, 2018 #22. 00. Screwfix Community Forum. Free next day delivery available. Extract and recirculate kitchen steam and fumes. Some of the hobs are pretty pants for sitting flat on the worktop. Control Type: Touch. Cheers mate. Oven is 880mm. re the oven, best if also connect this to the existing 32A circuit. Single oven, electric hob and cooker hood all fed off one 13A switched spur. MGW Screwfix Select. seneca Screwfix Select. Yes, all kitchen sockets are connected to the same 32-amp MCB. #26. 21. Various styles and finishes. 6. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric Oven and Electric Hob Discussion in ' Electricians' Talk ' started by RedRick , Nov 8, 2004 . Black Friday Deal. 2 x Ceramic Plates. robertpstubbs Screwfix Select. Safety Gas Cut-Out. The oven circuit is fused at 32A. It will most likely have a 45A switch on it. Screwfix customers rate this product 4. Only the sealing strip can be used. 6mm cable would give 32A (7. This being sufficient worktop to support the hob. View all: No Nonsense Spray Paints. 95Inc Vat. £72. Discount applied in basket. 0800 324 7818. The display on the touch control panel is fine. We currently have a built in electric oven, this is plugged in behind the. com. com. £23. PayPal accepted online. Bush A60CT Electric Ceramic Hob - Black. It worked fine for a while, but is now acting. Add to basket. Please do not return to store. rogerk101 Screwfix Select. g. stateit, Jan 11, 2014. Screwfix Community Forum. Hob wago connectors diynotDoes an electric oven craving to be hardwired Wiring in new oven and induction hob. More precise cooking. If their is an outlet plate on the wall behind the original cooker position, you can connect to this with the 2 extra cables. Side-mounted dial controls. 5kw respectively. Boost function. 5 mm cables. Improve Kitchen efficiency and hygiene. 49 Inc Vat. UK call centre ready for your call 24/7. 7kW. Click & Collect. You can learn more about the innovative features available on select Belling. Frustrated female New Member. hope someone can help clear this up. Available in several different options. The Happy Builder Screwfix Select. £269. The new items are max 2. alex250 New Member. Order online at Screwfix. Pay your way. Peter160482 New Member. Even heat distribution. 2 x Ceramic Plates. When kitcken was built I had a. Sepparate Ovens (in general) can be run off a socket outlet, and indeed come with a 3 pin plug attached. It provides a protective barrier between the hob cabinet and the underside of the hob. A lot of/maybe all oven/hob manufactures stipulate the use of heat and grease resistant flex to connect up, and not complying with said would constitute a nullification of guarantee/reg breach. 6mm twin and earth contains brown and blue conductor cores with a bare earth which are protected by a durable PVC sheath. Several light coats will give a better finish than a single heavy coat. The plug limits the maximum power output to 3 kW. View all: No Nonsense Spray Paints. Aeg. £109. Hob. Hannahx07 New Member. Heat-Resistant. Currently the oven is left disconnected. Neff N50 T26BB59N0 Cast Iron Gas Hob - Stainless Steel. 85 kg. Order Cooke & Lewis CSB60A Built- In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. If you had a gas hob, the minimum distance would be 150mm under the gas regs. €91. Also the supplied cable for the oven seems a bit lightweight to put into a connection plate. those are the cables supplied. Delivery 7 days a week 60 days free credit available. 2 x Ceramic Plates. £379. Each cooking plate has a separate neon indicator and the base of the hob. I have had a new aeg gas hob fitted. Touch-Dry in 1-2 Hours. Noise Level 40dBA at 3m. Hi Both front and back left hand side of hob wont work, both rings on right hand side is fine. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric hob & cooker connection. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Child /. 00. An induction hob is an electric hob, just has an increased power rating (normally) Dr Bodgit, Sep 13, 2017. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. VonShef Mini Oven 30L - 1600W Portable, Electric Multi-Function Cooker for Grilling, Baking & Roasting with Wire Rack. View all: MK Flex Outlets. There most certainly is regarding gas hobs, unless the sink is stainless steel or vitreous ceramic, it has to be a minimum of 150mm from the edge of the sink. As the electrician is busy. Designed for any type of glass or ceramic and especially vitro ceramic, this cleaner is safe to use on any electric or induction hob. Sun: 9am to 4pm. 10. Number of Cooking Zones: 2 Zones. Discussion in 'Just Talk' started by koolpc, Aug 27, 2022. We delve into the differences between ceramic, solid plate and. Bob Rathbone Screwfix Select. Timer. Timer. The ceramic glass absorbs and retains heat better than the solid plate design. UK call centre ready for your call. However you need to refer to the hob specs and check the gap required between the hob and cooker below. 9% APR representative (variable)* +1 more offers. If no flex is fitted ,likely to require hard wiring back to the CU, with local isolation, usually in adjacent cupboard or above worktop. Raised Slim Profile. 00. Ind spark Screwfix Select. 7kw loads and each has 1. JP. 3000w for 13A input. K Piezoelectric Gas Lighter. Discussion in ' Plumbers' Talk ' started by Peter160482, Mar 14, 2021 . Screwfix Select. But the hob draws 7. To install the new induction hob this needs to be hardwired. You need to seal the cut edge of the chipboard, otherwise if water gets under the hob, the chipboard will absorb it and swell up and ruin your worktop. 5cm. com. Mon - Fri: 7am to 8pm. This is why 3kW immersion heaters are on separate circuits. Sat: 7am to 6pm. (41) 5. 43/l) FREE delivery Wed, 4 Oct on your first eligible order to UK or Ireland. Opening hours & directions Open 7 days a week Click & Collect. can anyone help me ! i have replaced my electric hob but i am finding that the new hob is making the worktop heat up and getting warm is this. 1-800 932 230. The designer of the circuit has determined that the 32 amp MCB is the suitable OPD for the circuit. It's rated at 32 amp, recently got my entire fuse box re-done a few months back due to problems with it and I've no idea if this is supported. Induction Hob. Flexible zones - cook with large pans for big meals. Delivery 7 days a week. Unfortunately there are no regs for electric hobs of any type. Whether you’re more of a simple cook and heating up some soup or whipping up a quick stir-fry is your thing then we’ve got the perfect hob for you. . Hi I am fitting 3 electric hobs (domino hobs so 30cm induction/30cm grill/30cm teppanyaki) on an island with them being 3kw/3kw/3. Latest Offers At Screwfix. furious_customer Screwfix Select. Home Forums > Screwfix Community Forum > Plumbers' Talk > gas hob. 4. My wife would like to replace the range cooker with one that has an electric oven and an induction hob. Deals and Offers. 00. Weight. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. state-it, Oct 2, 2010. 2 KW (max. A 5 ring ceramic or induction hob though will be at least 700mm wide, but more likely 900mm wide with a cutout width of 680mm to 880mm. com. Basket. Option A i thought would be to remove the 2Gang cooker switch with switched 13amp single socket outlet, and change to a single cooker switch first and then connect a dual outlet plate, then connect the oven and 2 zone hob to the Dual outlet plate. 5 mm cables or 3x2. I too am wanting to do this. Need Help. Repair Service Action. currently have a dual fuel free standing cooker (gas hob electric oven) this is being changed for a built in oven and separate gas hob. You would use a dual cooker connection unit ,and connect both to it. 2 year guarantee. Paint over rust on cooker hob. 2A (=10. Splurge with prices up to £600. £72. Repair Service Action. 49 Inc Vat. 3/5. What is the standard way? Is it just a 6/10mm radial fed by a 32a MCB/RCBO, then onto a 45a DP switch above worktop, then onto a dual 45a plate outlet, then 2 feeds one to hob other to cooker?. Dimensions: (H)6cm x (W)60cm x (D)53cm. The regs allow a separate oven and hob to share the same supply and control unit provided that they are not more than 2 metres apart or from the control, that you apply diversity, that is you add the hob and oven current together, take the f1rst 10A of that total and add 30% of the remainder (add 5A if a socket is fitted to the cooker control, don't do. Bostik FP401 Fire Resistant Acrylic Sealant White 310ml (572JE) compare. Screwfix Community Forum. 0800 324 7818. com. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. Home delivery from 12th November **. Automatic On/Off Thermosensor. What sealer is most appropriate? This will be on the surface of the worktop so should be simple to remove later on if needed. Why not see if you can source an offcut of oak top and rebate the edges of it so it sits in neatly and mount the hob in that. 4. Each of the ovens is 5. My question is, what is an omnipolar cut. Discussion in 'Electricians' Talk' started by mb, Jun 9, 2004. Free next day delivery available. Alternatively you could take a 13A fused spur off the closest socket and connect the hob. Bob Rathbone Screwfix Select. 30 day money back guarantee. Child Safety Lock Mechanism. 5 mm flex. The cupboards, shelves etc above the hob are not allowed to overhang the hob, so a 600mm hob needs a 600mm minimum opening above it. Features 4 functions including grilling and plate warming. MK Logic Plus 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket White (17157) (25) compare. Now I'm not so sure. My induction hob, being cheap, has a noticeable pulse in power at lower settings but really doesn't bother us. 375. Buy Cooke and Lewis Appliances at Screwfix. Makes light work of removing heavy duty tape / sticker residue, tar, grease and wet paint. There must be gas regs about this sort of thing surely. Don't be tempted to use masses a small bead. Heat your home according to your daily routine with the Russell Hobbs RHPH2001 Ceramic Plug Heater. I'm currently changing my hob for a new one. We are replacing our gas hob. Home Forums > Screwfix Community Forum > Electricians' Talk > AG Electric Hob ? Discussion in 'Electricians' Talk' started by Sharon151, Jun 21, 2014. 2 If that is the only gas inlet you could consider running the. Total Product Weight. #3. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (73) compare. I suppose you would run the cable in/under the floor first (observing regs) and rise up into one of the base cabs. Why not put the cabinet in that the integrated oven will sit in then fit the oven. 56A) = 20. sinewave Screwfix Select. It is a new hob , New World ES60 016580 but an old model . The wiring for it has a dedicated switch at the consumer unit to a swicth on the wall at the back of the hob which then feeds to a double socket within the back of the kitchen unit. Buy any 10+ Save 10% - View Offer. Buy Electric Hobs at Screwfix. Or maybe you’re a culinary master after a hob that packs the. The hob comes with a 13amp plug so all that is needed is for her to plug this into an adjacent wall socket. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. The sensor touch panel with an LED screen is easy to. 6 A) - so a worst-case total of 10. Requires 25mm Back Box. Order online at Screwfix. sinewave, Mar 24, 2007. You need to fuse the cooker hood, and ideally the oven down after the cooker switch. 39. 2 x Plate Sizes. 85 kg. (21) £. The. The AEG Pure 3 hob combines a sleek, seamless design with responsive functions. Most CERAMIC hobs are rated above 3kW and also require a 32A radial circuit. Click & Collect. 95 Inc Vat. Add to wishlist. #11. Frustrated female New Member. Easy power isolation. Buy Hob Appliances at Screwfix. Delivered by our approved supplier, Find out more. Discussion in 'Plumbers' Talk' started by JamesSmith2019, Jul 7, 2023. com.